At the top right-hand section of the screen is the cycle count indicator. It
displays the number of completed tightenings for that mode (up to 999
tightenings). The counter increments by one at the end of each tightening
once the Reset button has been pressed.
For the most accurate results, the wrench should be pulled at a speed
between 10 and 80 degrees per second. The wrench should be held steady
while the Reset button is pressed.
Setting Torque Units
The units of displayed torque can be toggled between Metric and English
units by pressing the Units key on the front panel. The current units
selected are indicated in the center right-hand section of the screen.
The wrench can also display torque in units of different sizes. The following
procedure toggles the wrench units between Nm (or lb.ft.) and dNm (or
in.lb.).
1. Press the Reset button to power up the wrench.
2. Move the Mode Selection switch to Setup.
3. With the Reset button held in, use the Parameter Adjustment Knob to
select the Custom Setup Mode #107. The main display shows "---", and
the torque units are displayed in the center right-hand section of the
screen.
4. Hold the Reset button and press the Units button to choose units of Nm
and lb.ft. Press the Joint button to choose units of dNm and in.lb.
5. Press and hold the Reset button and rotate the Parameter Adjustment
Knob counterclockwise until the Custom Setup Mode number is below
20.