Ingersoll-Rand 4575759 Impact Driver User Manual


 
15
Sensor I® Expert User Manual
WRENCH OPERATION INSTRUCTIONS
General Information
NOTE
Exceeding maximum torque rating may cause damage to wrench or loss
of calibration.
The wrench should only be used for its intended purpose, i.e., for
tightening, loosening and auditing procedures. It should be operated using
a smooth steady pull at moderate speed on the wrench handle with feet
firmly placed on floor.
The use of extensions to the handle, or application of force to other parts of
the wrench may cause damage or result in personal injury, or may result in
inaccurate tightenings.
If the wrench fails to operate using the recommended procedures described
in this manual, the cause of malfunction should be corrected by an
authorized Ingersoll-Rand technician. For a list of authorized
Ingersoll-Rand service centers, see Appendix D.
Operation
Ensure the Power Switch is in the ON position and press the Reset button.
Primary Operation Modes
Throughout all the tightening modes there are some common features. At
any time during or at the end of a tightening the screen can be toggled to
display the following; Peak Torque (PK), Angle (An), and Dynamic Torque
(Tq). The present item displayed is indicated in the lower left hand portion
of the screen. This can be changed by pressing the Display key.