Ingersoll-Rand 4575759 Impact Driver User Manual


 
38
Sensor I® Expert User Manual
5. Move the mode selection switch to Torque Control.
6. With the Reset button held in, use the Parameter Adjustment Knob to
select the tightening mode for which the end of tightening data is to be
transmitted over the serial interface. Select from:
7. Release the Reset button once the tightening mode has been selected.
8. Press the Joint button and the tightening parameters, end of tightening
data and statistics will be transmitted.
9. Move the Mode Selection switch to Setup.
10. Press in the Reset button and adjust the Custom Setup Mode # below
20.
Tightening Curve Storage
Up to 10 tightening curves can be stored in the Sensor I® Expert Wrench for
later retrieval via the serial port. Tightening curves can be stored provided
the following conditions have not occurred: wrench has powered down, has
been switched to another tightening mode or another tightening has
commenced.
The following procedure shows how to store a tightening curve.
A- Angle Control
J- Yield (joint) Control
b- Dynamic Audit
t- Torque Control
1 through 20- Custom tightening modes 1-20