Sensor I® Expert User Manual
6. Membrane Keys
Each membrane key has two functions. To access the lower function,
simply press the key. The upper function can be accessed by holding
in the Reset button and then press the membrane key.
xCp When this key is pressed (with the Reset button held in), the Mean Value is displayed for
approximately 1.5 seconds, then the Cp Value is displayed until the Reset button is
released. Repeatedly pressing this key with the Reset button held in, will display Mean
and Cp values for Torque or Angle.
Window Press this key to display and edit the Torque and Angle high and low limits for a
particular tightening mode. Press this key again to go back to the tightening mode.
s/Cpk When this key is pressed (with the Reset button held in), the Standard Deviation is
displayed for approximately 1.5 seconds, then the Cpk Value is displayed until the Reset
button is released. Repeatedly pressing this key with the Reset button held in, will
display Standard Deviation and Cpk values for Torque or Angle.
Display Pressing this key changes the value that is being displayed on the screen. Each press
toggles the display between Peak Torque (Pk), Angle (An), Ld (not used), and Dynamic
Torque (Tq).
Units Pressing this key will change the torque units displayed for the selected mode. All stored
data will also be converted.
Clear Pressing this button (while Reset is held in) clears custom tightening modes. This key
also clears tightening data stored in memory.
Joint This button changes the joint type for Yield Control tightening.
Store Press this button (while Reset is held in) to store Curve Trace Data.