21
Sensor I® Expert User Manual
Yield Control
1. Press and release the Reset button to
power up the wrench.
2. Move the Mode Selection switch to Yield
Control.
3. Press the Units key to select the desired
Torque units.
4. Selects the joint hardness by pressing the
Joint key on the front panel (the joint
hardness currently selected is displayed in
the lower right corner of the screen).
5. Attach the angle reference arm (EA-models
only) to the wrench, and place the magnet
on a magnetic surface.
6. Press and hold in the Reset button. The
snug torque will be displayed.
7. With the Reset button held in, use the
Parameter Adjustment Knob to adjust the
snug torque to the desired value. The snug
torque value should be 30% to 50% of the
proof load torque expected for that bolt.