37
Sensor I® Expert User Manual
6. With the Reset button held in, use the Parameter Adjustment Knob to
select the desired tightening mode. Select from:
7. Release the Reset button once the tightening mode has been selected.
8. Press the Display button and the tightening parameters will be transmit-
ted.
9. Move the Mode Selection switch to Setup.
10. Press the Reset button and adjust the Custom Setup Mode number
below 20.
End of Tightening Data Dump
The Sensor I
®
Expert wrench stores end of tightening data for up to 1000
tightenings for each tightening mode. This final tightening data (Torque,
Angle and optional External Channel) can be uploaded to a PC by
completing the following:
1. Connect serial cable from the charger/data port to the serial port of the
computer.
2. Press the Reset button to power up the wrench.
3. Move the Mode Selection switch to Setup.
4. With the Reset button held in, use the Parameter Adjustment Knob to
select Custom Setup Mode #109. Note that an "A" appears on the main
display.
A- Angle Control
J- Yield (joint) Control
b- Dynamic Audit
t- Torque Control
1 through 20- Custom tightening modes 1-20