36
Sensor I® Expert User Manual
8. Holding in the Reset button, adjust the Custom Setup Mode number
below 20.
9. Release the Reset button and move the Mode Selection switch to the
desired tightening mode.
Parameter Dump
Once initiated the parameter dump function will dump out settings for a
particular tightening mode. A parameter dump can be performed on any
primary or custom tightening mode. It is recommended that once custom
modes have been setup that a parameter dump be initiated so there is a
permanent record of the wrench's settings. This is not necessary if the
wrench was programmed via the InterLink software.
NOTE
Tightening parameters of torque that are downloaded and uploaded in
units of Nm or lb.ft. are rounded to the nearest Nm or lb.ft. If higher
resolution or greater precision is required in the parameters that are
transmitted, use units of dNm or in.lb. Actual data points transmit with
a resolution of 1/10
th
of the units.
1. Connect the serial cable from the charger/data port to the serial port of
the computer.
2. Press the Reset button to power up the wrench.
3. Move the Mode Selection switch to Setup.
4. With the Reset button held in, use the Parameter Adjustment Knob to
select Custom Setup Mode #109. Note that an "A" appears on the main
display.
5. Move the Mode Selection switch to Torque Control.