18
Sensor I® Expert User Manual
4. Press and hold in the Reset button. (Initially the snug torque will be
shown, then after a few seconds the target toque will be shown). See
graphic below. Note the snug torque in Torque Control mode is not
adjustable and set to the minimum snug allowable as a default. The
default snug values for all models are listed in the TOOL DESCRIPTION
Technical data table in Chapter 2.
5. With the Reset button held in, use the Parameter Adjustment Knob to
adjust the target torque to the desired value. See graphic below.
6. Release the Reset button. If the Fault light is lit then press and hold the
Reset button again, while holding the wrench steady. Continue to hold
in the Reset button until the RUN light appears and the FAULT light
goes off. Release Reset.
7. Commence tightening with moderate speed steady pulls. Stop as soon as
the OK light comes on and the alarm sounds.