Ingersoll-Rand 4575759 Impact Driver User Manual


 
30
Sensor I® Expert User Manual
4. To read the standard deviation, σ, and process capability, CpK, repeat
the above procedure, but press the σ key in place of the x key. The stan-
dard deviation and CpK will be displayed for torque (Pk), and angle (An).
CUSTOM TIGHTENING MODES
The Sensor I
®
Expert wrench has the capacity to store up to 20 custom
configurations of the primary tightening modes. These modes are numbered
1 through 20 and are stored and accessed through the Setup Mode.
Setup and Storage of Custom Tightening Modes
1. Use the Mode Selection switch to select the primary tightening mode
from which the Custom Mode is to be setup, i.e., Torque Control,
Dynamic Audit, Yield Control or Angle Control.
2. Program all required control points and window limits.
3. Turn the Mode Selection switch to Setup. Hold in the Reset button, and
use the Parameter Adjustment Knob to select an empty custom mode.
Empty modes will be indicated by a flashing mode number between 1
and 20.
4. With the Reset button still held in, move the Mode Selection switch to
the primary tightening mode required and press the Store key.
5. Release the Reset button.