Ingersoll-Rand 4575759 Impact Driver User Manual


 
41
Sensor I® Expert User Manual
If while in a primary or custom tightening mode, the MUL symbol is on but
the user is unsure of the multiplier value, it can be checked by following the
procedure described in steps 2 and 3.
To disable a multiplier in a primary mode, follow the step by step procedure
to set the multiplier, but select 1.00 as the multiplier value.
1. Turn Mode Select switch to Setup mode.
2. Press and hold in the Reset button and rotate Parameter Adjustment
Knob until Custom Setup Mode #104 is indicated in the top right hand
corner of the display. Note the symbol "MUL" is indicated in the top cen-
ter of the display and the main display shows "---".
3. Rotate the Mode Select switch to the tightening mode for which the mul-
tiplier is to be enabled. This display should show 1.00.
4. While holding in the Reset button, press the Units key to step through
the multiplier values above. Pressing the Joint key will reset the multi-
plier value to 1.00.
5. To adjust the programmable value, begin with the display at "10.00" and
ensure that the Reset button is released. Rotate the Parameter Adjust-
ment Knob until the display shows the desired value. Increments are in
0.01 steps.
6. Rotate the Mode Select switch back to the setup position. The display
now should show "---" with "MUL" indicated.
7. Holding in the Reset button, adjust the Custom Mode number below 20.