Ingersoll-Rand 4575759 Impact Driver User Manual


 
34
Sensor I® Expert User Manual
7. Press in the Reset button and adjust the baud rate to the desired value
(valid baud rates are 19200, 9600, 4800, 2400, 1200 & 600).
NOTE
The last two numerals are not shown on the wrench display.
8. Move the Mode Selection switch to Setup.
9. Press in the Reset button and adjust the Custom Setup Mode number
below 20.
10. Release the Reset button and move the Mode Selection switch to the
desired tightening mode.
Data Out During Tightening
Once this function is activated, a torque data point will be transmitted via
the serial port for every degree increment of the tightening angle beyond
snug.
1. Connect the serial cable from the charger/data port to the serial port of
the computer.
2. Press the Reset button to turn on the wrench.
3. Move the Mode Selection switch to Setup.
4. With the Reset button held in, use the Parameter Adjustment Knob to
select Custom Setup Mode #101. Note: A symbol "RX" appears on the
left-hand side of the digital display and the main display shows "--.-".
5. Rotate the mode select switch to the tightening mode for which the
option is to be enabled. The display will show "OFF".