RECONNECT PROCEDURE
Multiple voltage machines are shipped connected
to the highest input voltage listed on the
machine's rating plate. Before installing the
machine, check that the Reconnect Panel in the
Input Box Assembly is connected for the proper
voltage.
Failure to follow these instructions can cause
immediate failure of components within the
machine.
__________________
To reconnect the machine to a different voltage,
change the position of the power straps (links) on
the reconnect panel assembly. Follow The Input
Supply Connection Diagram located on the inside
of the access door.
1. For 208/230/460 VAC machines, see
Figure A.3a.
2. For 460/575 VAC machines, see Figure
A.3b.
FIGURE A.3a-Voltage Link Positions for
208/230/460 VAC machines.
FIGURE A.3b - Voltage Link Positions for
460/575 VAC machines.
INSTALLATION
PRO-CUT 60
A-6
LINK POSITIONS
L1
460 V., 60HZ.
GND.
L2
LINK
LINK POSITIONS
L1
575 V., 60HZ.
GND.
L2
LINK
USE FERRULE
#10 AWG ONLY
LINK POSITIONS
L1
208 V., 60HZ.
GND.
L2
LINK
LINK POSITIONS
L1
230 V., 60HZ.
GND.
L2
LINK
LINK POSITIONS
L1
460 V., 60HZ.
GND.
L2
LINK
USE FERRULE
#10 AWG ONLY
460V
460V
575V
208V
230V