Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
PRO-CUT 60
HIGH VOLTAGE / HIGH
FREQUENCY AND BY-PASS
CIRCUIT
The control board passes the 115vac through the
CR2 relay contacts to the primary of the high volt-
age transformer. The secondary of the high volt-
age transformer delivers a high voltage to the
spark gap generator and also to the high frequen-
cy transformer. The high frequency transformer
transfers the high frequency "spark" to the
torch terminal. This momentary burst of high fre-
quency is used to ignite the pilot arc.
The by-pass board is necessary to prevent any
unwanted signals from interfering with the Pro-
Cut 60 circuitry.
THEORY OF OPERATION
E-3
FIGURE E.4 - High Voltage/High Frequency and By-Pass Circuit
NOTE: Unshaded areas of Block Logic
Diagram are the subject of discussion