INPUT IDLE AMPS
MAXIMUM ACCEPTABLE OUTPUT VOLTAGE -
AT MINIMUM OUTPUT SETTING
MINIMUM ACCEPTABLE OUTPUT VOLTAGE -
AT MAXIMUM OUTPUT SETTINGS
RECOMMENDED METERS FOR MACHINE OUTPUT TESTS
VOLTMETER: Analog type meter
TROUBLESHOOTING & REPAIR
PRO-CUT 60
F-52
RETEST AFTER REPAIR
Should a machine under test be
rejected for any reason requiring the
removal of any mechanical part that
could affect the machine’s electrical
characteristics, or if any electrical
components are repaired or
replaced, the machine must be
retested.
INPUT VOLTS / HERTZ
208 / 60
230 / 60
460 / 60
575 / 60
MAXIMUM IDLE AMPS
4.4
4.0
2.0
1.6
Output Control at Minimum
26 Amps @ 43VDC
Output Control at Maximum
60 Amps @ 90VDC
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC