Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
REMOVAL/REPLACEMENT
PROCEDURE
NOTE: See Figure F.17.
1. Disconnect input power to the
machine.
2. Perform the CAPACITOR
DISCHARGE PROCEDURE.
3. Disconnect the air line to the air
regulator on the Case Back
Assembly.
4. Remove the Case Back
Assembly Access Door.
5. Disconnect the input power
supply leads from the terminal
block.
6. Remove the six screws from the
Case Back Assembly. There are
two screws at the top and four at
the bottom. After the last screw
is removed, be prepared to use
a strap or other support to keep
the Case Back Assembly from
falling open. The motor leads
could be pulled out of their con-
nectors if this should happen.
7. Unscrew the brass air line con-
nector from the male elbow
using pliers or channel locks.
8. Remove the brass air line con-
nector and companion nylon
compression fitting.
TROUBLESHOOTING & REPAIR
PRO-CUT 60
F-47
FAN BLADE AND FAN MOTOR REMOVAL/REPLACEMENT
➀ FAN
➁ BRACKET
➂ MOTOR
➀
➁
➂
FIGURE F.17-Fan Blade & Fan Motor