Weight
Including Machine
Torch Cable (Length)
(25ft/7.6m) (50ft/15.2m)
322 lbs. 329 lbs.
146 kg. 149 kg.
INPUT - SINGLE PHASE / 60 HERTZ ONLY
RATED OUTPUT
OUTPUT
RECOMMEND INPUT WIRE AND FUSE SIZES
PHYSICAL DIMENSIONS
(INCLUDES LIFT BAIL AND UNDERCARRIAGE W/O HANDLE)
TECHNICAL SPECIFICATIONS - PRO-CUT 60
Standard Voltage
Duty Cycle
60% Duty Cycle
100% Duty Cycle
Current
Range
25-60 Amps
AC Input
Voltage at
60 Hertz
208/230
460/575
Fuse
(Super Lag)
Circuit Breaker
(Delay Type)
50 AMPS
25 AMPS
#8 (8.4mm
2
)
#10 (5.3mm
2
)
2 Input Supply Wires 1 Ground Wire
#10 (5.3mm
2
)
#10 (5.3mm
2
)
Type 75
o
C
Copper Wire in Conduit AWG (IEC) Sizes
Depth
22 in.
559 mm
Width
19 in.
483 mm
Height
34 in.
864 mm
Open Circuit
Voltage
MIN MAX
235VAC 280 VAC
For all plasma cutting applications
Based on U.S. National Electrical Code
Ambient Temperature 30oC or Less
Pilot Current
22.5A (20 seconds
out of 80
seconds)
AMPS
60
45
Volts at Rated Amps
115
115
Input Current at
Rated Output
Codes
208/230/460
460/575
50/45/23
23/18
10112, 9819
10118, 10096
INSTALLATION
PRO-CUT 60