Lincoln Electric SVM148-B Welder User Manual


 
ACCESSORIES
C-6 C-6
RANGER 300 D AND 300 DLX
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
CONNECTION OF THE LN-7 TO THE
RANGER (300 DLX ONLY) USING K584
CONTROL CABLE (SEE FIGURE C.4.)
1. Shut the welder off.
2. Connect the electrode cable from the LN-7 to the
ELECTRODE terminal of the welder. Connect the
work cable to the WORK terminal of the welder.
NOTE: Welding cable must be sized for current and
duty cycle of application.
NOTE: Figure C.4 shows the electrode connected for
positive polarity. Use the Polarity switch on the Ranger
300 DLX to select the desired electrode polarity.
3. Connect the K584-XX Control Cable to the LN-7.
4. Connect the K584-XX Control Cable to the 14-pin
amphenol on the Ranger 300 DLX.
5. Place the IDLER switch in the “HIGH” position.
Any increase of the high idle engine RPM by changing
the governor setting or overriding the throttle linkage
will cause an increase in the AC auxiliary voltage. If
this voltage goes over 140 volts, wire feeder control
circuits may be damaged. The engine governor set-
ting is preset at the factory - do not adjust above RPM
specifications listed in this manual.
6. Set the LOCAL/REMOTE switch to “REMOTE” if a
K857 remote control is used. Set the switch to
“LOCAL” if no remote control is used.
7. Set the OUTPUT RANGE switch to “WIRE WELD-
ING CV.”
8. Set the WELDING TERMINALS switch to “WELD-
ING TERMINALS REMOTELY CONTROLLED.”
9. Adjust wire feed speed at the LN-7.
NOTE: For remote control, a K857 remote control is
required. Connect it to the 6-pin amphenol.
FIGURE C.4
RANGER 300 DLX/LN-7 WITH K584 CONTROL CABLE CONNECTION DIAGRAM
CAUTION
ELECTRODE
TO WORK
TO LN-7 INPUT
CABLE PLUG
14 PIN
AMPHENOL
OPTIONAL K857
REMOTE CONTROL
6 PIN
AMPHENOL
ELECTRODE CABLE
TO WORK
TO WIRE FEED UNIT
K584 CONTROL CABLE