CONNECTION OF THE LN-8 TO THE
RANGER 300 (DLX ONLY) USING K867
UNIVERSAL ADAPTER (SEE FIGURE C.5.)
1. Shut the welder off.
2. Connect the electrode cable from the LN-8 to the
ELECTRODE terminal of the welder. Connect the
work cable to the WORK terminal of the welder.
NOTE: Welding cable must be sized for current and
duty cycle of application.
NOTE: Figure C.5 shows the electrode connected for
positive polarity. Use the Polarity switch on the
Ranger 300 to select the desired electrode polarity.
3. Connect the K867 Universal Adapter to the K196
input cable and the 14-pin amphenol of the Ranger
300 DLX as indicated in Figure C.5. Make the
proper connections for local or remote control
according to Figure C.5.
4. Connect the K196 input cable to the LN-8.
5. Place the IDLER switch in the “HIGH” position.
Any increase of the high idle engine RPM by changing
the governor setting or overriding the throttle linkage
will cause an increase in the AC auxiliary voltage. If
this voltage goes over 140 volts, wire feeder control
circuits may be damaged. The engine governor set-
ting is preset at the factory - do not adjust above RPM
specifications listed in this manual.
6. Set the LOCAL/REMOTE switch to “REMOTE.”
7. Set the OUTPUT RANGE switch to “WIRE WELD-
ING CV.”
8. Set the WELDING TERMINALS switch to “WELD-
ING TERMINALS REMOTELY CONTROLLED.”
9. Adjust wire feed speed and voltage at the LN-8.
FIGURE C.5
RANGER 300 DLX/LN-8 WITH K867 ADAPTER CONNECTION DIAGRAM
+
14 PIN
AMPHENOL
CV-
TO WORK
WIRE
FEEDER
K196
K867 UNIVERSAL
ADAPTER PLUG
INPUT CABLE
ELECTRODE CABLE
TO WIRE FEED UNIT
2
4
76
77
SPARE
82
81
INSULATE UNUSED
LEADS INDIVIDUALLY
}
21
GND
SPLICE LEADS
AND INSULATE
32
2
}
LN-8
75
31
32
42
GND
31
4
21
B
C
A
41
CAUTION