Section 2: Installing the 1700 Reader In-Sight
®
1700 Series Wafer Reader
8
Figure 2-3: I/O Expansion Module Connections
To connect an I/O Expansion Module to the In-Sight 1700 reader:
1 Verify the 24VDC power supply being used is switched off.
2 Optionally, connect the power and ground wires for the acquisition trigger input,
discrete outputs, and discrete inputs into their corresponding terminals on the
Expansion Module.
3 Optionally, connect the 9-pin male D-sub connector of an RS232 serial cable into the
corresponding 9-pin female connector on the Expansion Module.
4 Plug the Expansion Module Cable’s (P/N 300-0341-15) 15-pin male D-sub connector
into the corresponding female connector on the Expansion Module.
5 Plug the RJ-45 connector of the Expansion Module Cable into the In-Sight 1700
reader’s breakout port. The cable’s connectors are “keyed” to the notch in the
Breakout port.
6 Plug wire leads from a 24VDC supply for the +24V power and ground into the 2-pin
terminal plug labeled “Power Input” on the Expansion Module. Alternatively, remove
the terminal plug and insert the 2-pin terminal plug attached to the (optional) In-Sight
power adapter into the keyed power adapter port on the Expansion Module (Figure
2-3).
7 Restore power to the 24V supply. The red power LED on the reader and the +24V
LED on the Expansion Module will indicate that the reader and Expansion Module
are receiving power.