Section 7: Native Mode Commands In-Sight
®
1700 Series Wafer Reader
82
7.6.6 SetConfigFieldDef
SetConfigFieldDef(<WafID>,<Config>,<FieldDef>)
Defines the Field String when Mark specifies a character string or barcode.
NOTE The FieldDef Input must be set off with quotation marks.
Inputs: WafID, Config, FieldDef
Outputs: Status Code, # of bytes
Sample Input and Output
EV SETCONFIGFIELDDEF(A4,0,"A=A;B=B")
1
0
7.6.7 SetConfigFieldString
SetConfigFieldString(<WafID>,<Config>,<FieldString>)
Specifies the number of characters contained in the character string or encoded in a
barcode.
NOTE The FieldString Input must be set off with quotation marks.
Inputs: WafID, Config, FieldString
Outputs: Status Code, # of bytes
Sample Input and Output
EV SETCONFIGFIELDSTRING(A 4,0,"************")
1
0
7.6.8 SetConfigLightMode
SetConfigLightMode(<WafID>,<Config>,<LightMode>)
Specifies either a Bright Field or a Dark Field illumination effect on the mark.
Inputs: WafID, Config, LightMode
Outputs: Status Code, # of bytes