1700 Series Wafer Reader Section 7: Native Mode Commands
63
7.1.3 Set Online
SO[int]
Sets the In-Sight system into Online or Offline mode.
NOTE: This command cannot set the In-Sight system Online if it was previously set Offline manually
through the user interface, or by a discrete input signal.
Inputs: 0 to set In-Sight Offline, and 1 to set In-Sight Online.
Output: Status Code.
The status codes are:
STATUS CODE DESCRIPTION
1 The command was executed successfully.
0 Unrecognized command.
-1 The value given for int is either out of range, or is not a valid integer.
-5
The communications flag was successful but the system did not go Online because the
system is set Offline manually through the user interface or the Discrete I/O setting is off.
Sample Input and Output
SO 1
1