In-Sight
®
1700 Series Wafer Reader Section 7: Native Mode Commands
61
EVALUATE EXTENDED NATIVE MODE COMMANDS (GET AND SET)
EV GetWaferAcqEnable
EV SetWaferAcqEnable
The status of the Disable Acquire setting.
EV GetWaferAll All results for the most recent read, and settings for all Configs.
EV GetWaferAvgScore The average raw response scores for all Configs that passed.
EV GetWaferBestConfig The index of the Config that passed during the last read.
EV GetWaferFixCol The column coordinate of the fixture.
EV GetWaferFixRow The row coordinate of the fixture.
EV GetWaferFixTheta The orientation of the fixture.
EV GetWaferNumFailed The number of failed reads for all Configs.
EV GetWaferNumPassed The number of passed reads for all Configs.
EV GetWaferOrder
EV SetWaferOrder
The index of the Read Order setting.
EV GetWaferSummary A summary of the results for the most recent read.
EV GetWaferTimeout
EV SetWaferTimeout
The total amount of time (in seconds) to allow for a read.
For more information on these commands, refer to the In-Sight Guide & Reference HTML
Help file, included in the installation package.
7.1 Native Mode Commands
The following Native Mode commands are used to remotely control an In-Sight 1700 from
user-designed software. Each command returns a Status Code, the number of characters
(in bytes, including Carriage Returns and Line Feeds) in the output that follows, and the
results.
7.1.1 Abort Execution
AE[2]
Terminates the current execution of the WafID function within the spreadsheet. Unlike
most Native Mode commands, no status code is returned after the Abort Execution
command is executed, but depending on the function that is terminated, other information
may be returned.
Input: 2
Sample Input and Output
NOTE In this sample, Abort Execution causes the current read operation to terminate.
AE2
SM"READ"0
1
AE2
[UH587IX1CGC3,390.000,1.000]