A SERVICE OF

logo

59
7 Native Mode Commands
In this section…
7.1 Native Mode Commands .........................................................................................61
7.2 Put Extended Native Mode Commands ..................................................................64
7.3 Inputs and Outputs ..................................................................................................66
7.4 Evaluate Extended Native Mode Commands (Actions) ..........................................69
7.5 Evaluate Extended Native Mode Commands (Get).................................................72
7.6 Evaluate Extended Native Mode Commands (Set) .................................................80
The In-Sight 1700 reader supports many Native Mode commands that allow the reader to
be controlled from users’ custom application programs over Ethernet or serial port.
NOTE When logging on to an In-Sight system through Telnet from a Unix-based platform, the In-Sight
system’s host name (or IP Address) and port number (usually 23) must be added to the command
line. For example: >telnet is170060b 23. Supplying the port number disables the Unix
username/password authentication and forces the Unix system to prompt you for User Name and
password.
Below is a partial listing of the Native Mode commands typically used to control the 1700
remotely.
NATIVE MODE COMMANDS
Abort Execution Terminates the current execution of the WafID function within the spreadsheet.
Send Message
Sends an ASCII string to an In-Sight spreadsheet over a Native Mode connection, and
optionally, triggers a spreadsheet Event.
Set Online Sets the In-Sight system into Online or Offline mode.
PUT EXTENDED NATIVE MODE COMMANDS
Put live Turns live acquisition on/off.
Put portnum Specifies the network port used by In-Sight to transfer data and live images.
Put watch Returns the data contained in the specified cell when the cell is updated.
EVALUATE EXTENDED NATIVE MODE COMMANDS (ACTIONS)
EV AcquireConfig Acquires an image using a Config’s light settings, but does not read.
EV ReadConfig Reads using the specified Config.
EV TuneConfig Tunes a specific Config and optionally, saves the optimized settings.
EV ResetStats Reset all accumulated read statistics.