![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/3/59/3594b810-7359-4f03-9be3-dd231593bac1/3594b810-7359-4f03-9be3-dd231593bac1-bg4b.png)
In-Sight
®
1700 Series Wafer Reader Section 7: Native Mode Commands
69
7.4 Evaluate Extended Native Mode Commands
(Actions)
The following commands are used in conjunction with the Evaluate extended Native
Mode command to remotely control an In-Sight 1700 from user-designed software. Each
command returns a Status Code, the number of characters (in bytes, including Carriage
Returns and Line Feeds) in the output that follows, and the results (in XML format).
The status codes for all Evaluate commands are:
STATUS CODE DESCRIPTION
1 The command was executed successfully.
0 Unrecognized command.
-2 The command could not be executed.
7.4.1 AcquireConfig
AcquireConfig(<WafID>,<Config>)
Acquires an image using the light settings in the specified Config. This command does
not read.
Inputs: WafID, Config
Output: Status Code, # of bytes
Sample Input and Output
EV ACQUIRECONFIG(A4,0)
1
0
7.4.2 ReadConfig
ReadConfig(<WafID>,<Config>,<AcquireFlag>)
Reads using the specified Config.
Inputs: WafID, Config, AcquireFlag
Outputs: Status Code, # of bytes, Passed, String, Score, TryLog, TuneLog, LastRead,
NumPassed, NumFailed, NumTunePassed, NumTuneFailed, AvgScore, High, Wide,
Theta, Char, Value (Orc), Row (Orc), Col (Orc)