![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/3/59/3594b810-7359-4f03-9be3-dd231593bac1/3594b810-7359-4f03-9be3-dd231593bac1-bg59.png)
In-Sight
®
1700 Series Wafer Reader Section 7: Native Mode Commands
83
Sample Input and Output
EV SETCONFIGLIGHTMODE(A4,0,11)
1
0
7.6.9 SetConfigLightPower
SetConfigLightPower(<WafID>,<Config>,<LightPower>)
Controls the effective intensity of the LEDs on the mark by increasing the exposure time
of the 1700’s CCD imager.
Inputs: WafID, Config, LightPower
Outputs: Status Code, # of bytes
Sample Input and Output
EV SETCONFIGLIGHTPOWER(A4,0,25.123)
1
0
7.6.10 SetConfigMark
SetConfigMark(<WafID>,<Config>,<Mark>)
Specifies the type of wafer mark the selected Config will read.
Inputs: WafID, Config, Mark
Outputs: Status Code, # of bytes
Sample Input and Output
EV SETCONFIGMARK(A4,0,1)
1
0
7.6.11 SetConfigRegion
SetConfigRegion(<WafID>,<Config>,<Row>,<Col>,<High>,<Wide>)
Sets the region where the wafer mark is expected to appear in the field of view for the
specified Config.
Inputs: WafID, Config, Row, Col, High, Wide
Outputs: Status Code, # of bytes