1700 Series Wafer Reader Section 3: Configuring a Wafer ID Application
39
Also, the Text Mode settings in the Text Mode Details dialog (shown in Figure 3-11)
should be configured as follows:
! Fixed Input Length = 6
! Input Terminator = 13
! Output Terminator = 13
Figure 3-11: Text Mode Details Dialog
When using the In-Sight protocol, a Read can either be done on a single Config using the
READ(<Config>) command, or on all enabled Configs using the READ command; this
command uses the Read Order selected in the Options tab (see Section 3.5.1 Read).
Also, if ‘–1’ is used for the Config number to be read, the command is the same as using
the READ command. Tuning is done on a single Config using the TUNE(<Config>)
command. If the READ command needs to be terminated before the Read Timeout (see
Section 3.5.1) is exhausted, the Abort Execution Native Mode command can terminate
the READ execution. For more information on the Abort Execution command, refer to
Section 7: Native Mode Commands.
When In-Sight is the selected Protocol, the Output String will be a character string for a
successful read. For a failed read, the output will either be a partial read (where
unreadable characters are displayed as question marks) or a string of asterisks. The type
of output is dependent on the Score (see Section 5.1.6: Score).