Lincoln Electric SVM146-A Welder User Manual


 
PRIMARY POWER BOARD RESISTANCE TEST AND
CAPACITOR VOLTAGE TEST
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or
machine operator and will invalidate your factory warranty. For your safety and to avoid elec-
trical shock, please observe all safety notes and precautions detailed throughout this manu-
al.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
DESCRIPTION
This test will determine if the primary power board has any “shorted” or “leaky” power diodes
or Insulated Gate Bipolar Transistors (IGBTs). Also it will help to indicate any “shorted” input
filter capacitors.
MATERIALS NEEDED
Analog voltmeter/ohmmeter (multimeter)
Wiring Diagram
7/16” Wrench
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-15 F-15
PRO-CUT 80
WARNING
This procedure takes approximately 25 minutes to perform.