INSTALLATION
A-3 A-3
PRO-CUT 80
TECHNICAL SPECIFICATIONS (Cont’d) - PRO-CUT 80
GAS REQUIREMENTS
Required Gas Flow Rate Required Gas Inlet Pressure
70 PSI @ 480 SCHF 80 to 150 PSI
(4.8 Bar. @ 13550 LHR) (5.4 Bar. to 10.2 Bar.)
RECOMMENDED INPUT WIRE AND FUSE SIZES
For all plasma cutting applications based on U.S. National Electrical Code
Ambient Temperature 30°C or Less
AC Input Voltage Fuse (Super Lag) Type 75°C
at Circuit Breaker Copper Wire in Conduit AWG
60 Hertz (Delay Type) (IEC) Sizes
230VAC Single Phase 100 Amps #4 (21.1mm
2
) #4 (21.1mm
2
)
460VAC Single Phase 60 Amps #8 (8.4mm
2
) #8 (8.4mm
2
)
230VAC Three Phase 60 Amps #8 (8.4mm
2
) #8 (8.4mm
2
)
460VAC Three Phase 40 Amps #10 (5.3mm
2
) #10 (5.3mm
2
)
PHYSICAL DIMENSIONS
Height Width Depth Weight with
Torch Cable
16.5 Inches 13.75 Inches 29.5 Inches 98 lbs. (44.5 kg.)
419 mm 349 mm 749 mm (25 ft. cable)
113 lbs. (51.4 kg.)
(50 ft. cable)