Lincoln Electric SVM146-A Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-18 F-18
PRO-CUT 80
PRIMARY POWER BOARD RESISTANCE TEST AND
CAPACITOR VOLTAGE TEST (continued)
CAPACITOR VOLTAGE TEST
This test will help the technician to determine if
the input filter capacitors are being charged
equally to the correct voltage levels.
NOTE: This test should only be conducted with
the PRO-CUT 80 connected for 400 VAC or
above, and with the appropriate input voltage
applied.
TEST PROCEDURE
1. Remove main input power to the PRO-CUT
80.
2. Perform the Input Filter Capacitor
Discharge Procedure detailed earlier in
this section.
3. Locate and familiarize yourself with the
capacitor test locations on the primary
power board. See Figure F.3.
4. The following tests will be performed with
the input power applied to the PRO-CUT
80. BE CAREFUL. ALWAYS REMOVE
THE INPUT POWER AND PERFORM THE
INPUT FILTER CAPACITOR DISCHARGE
PROCEDURE BEFORE TOUCHING ANY
MACHINE COMPONENT.
ELECTRIC SHOCK can kill.
Have an electrician install and
service this equipment.
• Turn the input power off at the
fuse box before working on
equipment.
Do not touch electrically hot parts.
5. Apply the correct input power
and turn ON
the PRO-CUT 80.
NOTE: This test should only be conducted
with the PRO-CUT 80 reconnect
switch and “A” jumper configured for
400 VAC and above.
WARNING