Lincoln Electric SVM151-A Welder User Manual


 
Average AMPS for about 7 seconds after welding
stops in CC and CV modes only.
• The 5 second memory display is indicated by the
display’s left-most decimal point blinking, and is
interrupted if arc is restarted.
Accuracy of Actual AMPS is within 3%, and typical-
ly within 10 amps of Preset.
An Actual AMPS meter calibration adjustment
trimmer is provided. (See the Maintenance sec-
tion).
Two front screws secure the meter bezel, which
holds a replaceable spatter shield lens (Lincoln
part no. T14807-9).
(4) VOLTS Digital Meter is a 3-1/2 digit LED meter
which displays:
Preset VOLTS in CV mode when not welding.
“Blank” in CC mode when not welding.
Actual VOLTS while welding in both CV and CC
modes.
Average VOLTS for about 7 seconds after welding
stops in CV and CC modes only.
• The 7 second memory display is indicated by the
display’s left-most decimal point blinking, and is
interrupted if arc is restarted.
Accuracy of Actual VOLTS is within 3%, and typi-
cally within 1 volt of Preset.
• An Actual VOLTS meter calibration adjustment
trimmer is provided. (See the Maintenance sec-
tion).
Two front screws secure the meter bezel, which
holds a replaceable spatter shield lens.
(5) Thermal Shutdown (yellow) Light turns on if out-
put is shutdown because internal overheating has
occurred. (See Over Temperature Shutdown in
this section).
(6) Input Voltage (green) Light indicates appropriate
level of input supply voltage:
“On” for adequate input voltage over 50 V for CC or
CV mode.
“Off” for inadequate input voltage under 50 V, no
input or Power Switch OFF.
NOTE: If green light is “blinking,” the input voltage may
be drifting above and below the 50 V level due to loads
on supply and cables. This may also cause the input
contactor to “chatter.”
RECESSED PANEL CONTROLS
These instruments are recessed behind a screw-
secured hinged cover panel, and are not typically
required for normal operator access. They may be left
covered, as factory set, or set up as desired with or
without the hinged cover secured:
(7) Hot Start Control is provided to enhance arc
starting in both CC and CV modes with an extra
output “boost” at the arc strike that returns to the
setting level in less than a second (about 0.30
sec. in CC mode, and 0.045 sec. in CV mode).
This extra Hot Start amplitude is adjustable from
“0” (no extra) to “10” (100% of setting extra), with
the factory set “5” (center) position typically good
for most weld starting. However, “0” may provide
smoother starting for fine wire CV MIG.
(8) Arc Force Control is only functional in the CC
mode with Stick/Gouge slope. (See below). Arc
Force prevents “stubbing” of the electrode by pro-
viding extra weld current if the arc voltage drops
below about 14 V. This extra weld current is
adjustable from “-10” (no extra) to “+10” (60% of
setting extra), with the factory set “0” (center)
position typically good for most welding.
(9) CC Slope Switch is provided to enhance stick
welding on “fast-freeze” type electrodes (such as
E6010 and E7010) typically used on pipe welding
applications for fast root pass vertical down
"drag" technique (not “whipping”). For this type of
application, improved operating appeal may be
obtained if the CC Slope is switched from the fac-
tory set STICK/GOUGE position to the PIPE
position.
NOTE: The PIPE position uses a “drooping” type
slope (~22v/100A), so preset current (not actual
current) accuracy may be affected if arc length
voltage is not maintained at the typical 28 V used
for these electrodes. Typically this error should
not be more than about 10 A.
(10) Remote Control Receptacle is provided to per-
mit the use of an optional Remote output control
to provide operator control even closer to the arc.
Connecting the Remote plug to this receptacle
automatically transfers output control from the
panel Output Control (item (2) above) to the
Remote pot control, which will function the same
but with only single-turn resolution.
B-7 B-7
OPERATION
MULTI-WELD 350
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC