PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
OUTPUT PROBLEMS
Major physical or electrical damage
is evident.
1. Contact your local Lincoln
Authorized Field Service
Facility.
1. Contact the Lincoln Electric
Service Department at 1-800-
833-9353 (WELD)
The Multi-Weld 350 is completely
dead. The meters do not light and
the input contactor does not acti-
vate when the ON/OFF Mode
Selector switch is turned on.
1. Make sure the power source is
working properly and supplying
at least 50VDC to the Multi-
Weld 350. The electrode cable
must be positive polarity and the
work cable negative polarity.
2. Check the electrode and work
cables for loose or faulty con-
nections.
1. Measure the input voltage to the
Multi-Weld 350. It must be
between 50 and 113VDC.
2. The ON/OFF Mode Selector
switch (S1) may be faulty.
Check and replace if faulty. See
the Wiring Diagram. Also check
associated wiring.
3. The input diode D1/D2 may be
open. Check. See the Wiring
Diagram.
4. Perform the DC Buss Supply
Board Test.
5. Perform the Analog Control
Power Supply Board Test.
6. The Weld Control Board may be
faulty. Replace.
F-4 F-4