Lincoln Electric SVM151-A Welder User Manual


 
CONNECTION OF THE LN-25 TO THE
MULTI-WELD 350 “ACROSS THE ARC”
(SEE FIGURE C.1.)
1. Shut the welder off.
2. Connect the electrode cable from the LN-25 to the
+ terminal of the welder.
NOTE: Welding cable must be sized for current and
duty cycle of application.
3. Attach the single lead from the LN-25 to the work
using the spring clip on the end of the lead. This is
only a sense lead it carries no welding current.
If you are using an LN-25 without an internal contactor,
the electrode will be HOT when the Multi-Weld 350 is
turned ON.
4. Set the MODE switch to CV.
5. Adjust wire feed speed at the LN-25.
6. Adjust the HOT START CONTROL to the desired
level. (Use O for fine wire.)
7. Set VOLTMETER switch to the positive position.
C-3 C-3
ACCESSORIES
MULTI-WELD 350
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
AMPHENOL
TO WORK
WORK CLIP LEAD
LN-25
WIRE FEEDER
OPTIONAL K444
REMOTE CONTROL
TO WORK
ELECTRODE
6 PIN
TO WORK
CAUTION
FIGURE C.1
MULTI-WELD 350/LN-25 ACROSS THE ARC CONNECTION DIAGRAM