Lincoln Electric SVM153-A Welding System User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-56 F-56
COMMANDER 500
This is the typical TIG MODE output
voltage generated from a properly
operating machine. Note that each
vertical division represents 10 volts
and that each horizontal division rep-
resents 50 microseconds in time.
The machine was loaded with a resis-
tance grid bank to 200 amps at 16
VDC.
SCOPE SETTINGS
Volts/Div.....................10V/Div.
Horizontal Sweep...50 ms/Div.
Coupling.............................DC
Trigger.........................Internal
NORMAL TIG MODE VOLTAGE WAVEFORM
LOADED TO 200A 16 VOLTS
0 volts
10V
50ms