Lincoln Electric SVM153-A Welding System User Manual


 
TROUBLESHOOTING & REPAIR
F-36 F-36
COMMANDER 500
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
GREEN
GROUND
LEAD
OUTPUT PANEL
SCREWS
OUTPUT LEADS
(BEHIND PANEL)
FIGURE F.14 OUTPUT PANEL REMOVAL
STATOR VOLTAGE TEST (CONTINUED)
6. Using the 3/8" wrench, remove the three
screws holding the lower front panel (output
panel) to the case front assembly. Then
remove the front two screws holding the top
of the panel. These are accessed in the
control box, on the bottom at each side of
the box. See Figure F.14. Carefully move
the lower front panel to the right side. Note
the green ground lead will still be attached.