RETEST AFTER REPAIR (CONTINUED)
TOUCH START TIG MODE OUTPUT
Mode Selector Open Circuit Short Circuit
Switch Fine Control Voltage Current
TIG 20 - 250 A Maximum 14.0 - 15.8 25 - 27
TIG 20 - 250 A Minimum 12.0 - 13.8 21 - 24
AUXILIARY POWER OUTPUT
230 Volt Receptacle 115 Volt Receptacles
Open Circuit Open Circuit
Voltage Load Volts Load Amps Voltage Load Volts Load Amps
245 - 254 225 - 240 50 118 - 132 112 - 128 15