Lincoln Electric SVM153-A Welding System User Manual


 
A-2 A-2
INSTALLATION
COMMANDER 500
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TECHNICAL SPECIFICATIONS - COMMANDER 500 (K1639-1 & -2)
Make/Model Description Speed (RPM) Displacement Starting Capacities
System
Deutz 3 cylinder 44 HP(33 kw) High Idle 1900 173 cu. in 12VDC battery Fuel: 25 gal.
F3L 912 @ 1800 RPM Low Idle 1475 (2.83 L) & Starter 94.6 L
Diesel Engine Full Load 1800
Bore x Stroke Oil: 9.5 Qts.
9.0 L
3.94” x 4.72”
(100mm x 120mm)
Duty Cycle Welding Output Volts at Rated Amps
100% 500 Amps (DC multi-purpose) 40 Volts
60% 550 Amps (DC multi-purpose) 36 Volts
50% 575 Amps (DC multi-purpose) 35 Volts
Welding Range Open Circuit Voltage Auxiliary Power
1
30 - 575 Amps CC/CV 80 Max OCV @ 1900 RPM 120/240 VAC
12,000 Watts, 60 Hz.
20 - 250 Amps TIG 100% Duty Cycle
Height
2
Width Depth Weight
42.0 in. 31.5 in. 63.1 in. 1638 labs. (743 kg)
1966.8 mm 800.1 mm 1602.7 mm (Approx.)
INPUT - DIESEL ENGINE
OUTPUT - WELDER AND GENERATOR
PHYSICAL DIMENSIONS
1
Output rating in watts is equivalent to volt-amperes at unity power factor.
Output voltage is within +/- 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.
2
Top of enclosure. Add 8.9” (226.1mm) for exhaust.
RATED OUTPUT - WELDER