INPUT IDLE AMPS AND WATTS
MAXIMUM OUTPUT VOLTAGES
TROUBLESHOOTING & REPAIR
F-77 F-77
POWER WAVE 455/R
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
RETEST AFTER REPAIR
Input Volts/Hertz
208/60
230/60
400/60
460/60
575/60
Maximum Idle Amps
4.0
3.3
2.1
2.0
1.8
Maximum Idle KW
0.45
0.45
0.45
0.45
0.45
Input Volts/Hertz
208/60
230/60
400/60
460/60
575/60
50-70 VDC 48.5 - 55 VDC
OCV
115 - 123 VAC
10 Amp Load
111 - 119 VAC
Output Terminals
- No load
X1 - X2 115 Volt Receptacles