OUTPUT PROBLEMS
The Power Wave 455R does not
have welding output. The main
input contactor CR1 is not activat-
ing.
1. Turn the input power off and
make certain the reconnect
panel is configured correctly for
the applied input voltage.
2. If the Thermal light is lit, the unit
may be overheated. Let the
machine cool and adjust weld-
ing load and /or duty cycle to
coincide with the output limits of
the machine.
1. Perform the Input Contactor
Test.
2. Perform the Input Board Test.
3. Perform the T1 Auxiliary
Transformer Test.
4. Perform the Input Rectifier
Test.
5. Perform the Switch Board Test.
6. Perform the Power Board Test.
7. The Control Board may be faulty.
F-6 F-6
TROUBLESHOOTING & REPAIR
POWER WAVE 455/R
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
The thermal light is lit. The
machine regularly "overheats."
1. The welding application may be
exceeding the recommended
duty cycle and/or current limits
of the machine.
2. Dirt and dust may have clogged
the cooling channels inside the
machine. Refer to the Maint-
enance Section of this manual.
3. Air intake and exhaust louvers
may be blocked due to inade-
quate clearance around the
machine.
4. Make sure the fan is functioning
correctly. Machines above code
10500 are equipped with F.A.N.
(fan as needed) circuitry. The
fan runs whenever the output is
enabled, whether under load or
open circuit conditions. The fan
also runs for a period of time
(approximately 5 minutes) after
the output is disabled.
1. One of the thermostats may be
faulty. Also check associated
wiring for loose or faulty con-
nections. See the Wiring
Diagram.