TABLE F.5 INPUT BOARD VOLTAGE CHECKS
INPUT BOARD TEST(CONTINUED)
TEST POINTS
PLUG J61 PIN 8 (H1D)
TO
PLUG J61 PIN 2 (612)
PLUG J61 PIN 10 (T3)
TO
PLUG J61 PIN 2 (T1)
PLUG J60 PIN 3 (238)
TO
PLUG J60 PIN 4 (604)
PLUG J60 PIN 3 (238)
TO
PLUG J60 PIN 5 (232)
LEAD
NUMBERS
J61
J61
J60
J60
EXPECTED
VOLTAGE
READINGS
SAME AS
INPUT
VOLTAGE
A LITTLE LESS
THAN INPUT
VOLTAGE
13 15 VDC
13 15 VDC
COMMENTS
Present when Input
Switch SW1 is closed.
This is Pre-Charge Voltage and
will normally be present 6 sec-
onds after activating Input Switch
SW1. The Pre-Charge Voltage
should remain for approximately 6
seconds and then be removed.
This is the Coil Voltage for the
Pre-Charge Relay. Normally this
DC Voltage will be present 6 sec-
onds after Input Switch SW1 is
activated. This 13 - 15 VDC will
remain for approximately 6 sec-
onds and then be removed. The
Relay is controlled by the Control
Board. See the Wiring Diagram.
This is the DC Coil Voltage for the
Control Relay. Normally this DC
Voltage will be present approxi-
mately 12 seconds after Input
Switch SW1 is activated. The
Relay is controlled by the Control
PC Board. See the Wiring
Diagram.
#612
H1D
T1
T3
#238
#604
#238