Chapter 3 System Controller Alphabetical Command Reference 37
See Also
disablecomponent, showcomponent, and the Sun Fire 6800/4810/4800/3800
Systems Platform Administration Manual for step-by-step procedure on removing a
component from the blacklist. This information is in the ‘Troubleshooting” chapter
in the section “Disabling Components.”
Examples
CODE EXAMPLE 3-17 enables CPU/Memory board sb4. This removes CPU/Memory
board sb4 from the blacklist.
CODE EXAMPLE 3-18 enables I/O assembly 6, port 1. This removes port 1 of I/O
assembly 6 from the blacklist.
CODE EXAMPLE 3-17 enablecomponent Command Example Enabling CPU/Memory
Board 4
schostname:A> enablecomponent sb4
CODE EXAMPLE 3-18 enablecomponent Command Example Enabling I/O Assembly 6
and Port 1
schostname:A> enablecomponent ib6/p1