Sun Microsystems 6800/4810/4800/3800 Welding System User Manual


 
40 Sun Fire 6800/4810/4800/3800 System Controller Command Reference Manual October 2001
Note Any time the firmware is upgraded, check the Install.info file for the
firmware upgrade procedure. This file is provided with your latest software release.
Also refer to the Release Notes for any notes or special procedures.
If you install a replacement board into the system:
1. Check if the firmware level of the replacement board is the same as the board you
replaced. Incompatible boards are noted by the Failed board state in the output
of the showboards command.
2. If the board level is not the same as the board you replaced, perform the
flashupdate procedure on the board.
3. If a board was noted by the Failed state in showboards, after you
flashupdate a compatible version, power off the board to clear the Failed
state.
Before you update the flash images, make sure the firmware on the replacement
board is compatible with the firmware of the board you are replacing for scapp,
CPU/Memory board, and I/O assembly PROMs. New firmware is loaded if you
reboot the domain or turn the domain keyswitch off with setkeyswitch off and
then turn it on with setkeyswitch on.
To determine the version number of the current firmware:
1. Use the showboards -p proms command.
2. Compare the x.y.z number format. If x and y are the same, then the flash images
are compatible.
The new firmware may also contain a new rtos image. If the rtos image that is
currently installed is different than the rtos supplied with the software, you
must upgrade the rtos image.
To determine the version number of the current rtos:
1. Use showsc. The README file contains the version number of the new rtos
image.
There is currently no method to determine that the scapp and rtos versions are
compatible.
Note If you fail to check all versions, the domains can crash or the system
controller would fail to reboot normally.