MatrixPRO • 8x8 DVI Router • User’s Guide 43
4. Operation
Using the Main Menu
~ If All is selected and all equalization values do not match, the label “Not
All Same” is shown.
~ If an individual input is selected, its equalization value is shown.
6. Rotate the ADJUST knob and select the desired equalization value.
7. Press SEL to “accept” the new resolution, or press ESC to return to the current
value without making changes. If you accept the new value, visually check the
quality of the signal on the monitor.
8. As required, repeat step 5 to obtain the optimum quality signal.
9. (Optional) If required:
~ Scroll to the “Set to Default” line and press SEL to reset the equalization
value for all inputs to the default value to 4.
~ Scroll to the “Set to Maximum” line and press SEL to set the value to 15.
~ Scroll to the “Set to Minimum” line and press SEL to set the value to 0.
qÉëí=m~ííÉêå=jÉåì
From the Main Menu, select Test Pattern to display the Test Pattern Menu.
Figure 4-14. MatrixPRO Test Pattern Menu (sample)
The Test Pattern Menu enables you to perform the following functions:
Pre-select which test pattern will be displayed when the TEST PAT button is
routed to an output. One pattern can be set for all outputs, or individual test
patterns can be set on an output-by-output basis. The menu itself does not
enable the route.
Set the “global” output resolution of the test pattern.
Enable the Raster Box for a “test pattern” route already in effect.
Menu instructions are provided in the following sections:
Using the Test Pattern
Using the Raster Box
Note
If you selected All, but all equalization values currently do not
match, you will overwrite all “differing” values with a new
“global” equalization value.
TEST PATTERN
> 1400x1050 @59.94
Output All
Type H Ramp