Barco 26-0503000-00 Router User Manual


 
92 MatrixPRO • 8x8 DVI Router • User’s Guide
_K==oÉãçíÉ=`çåíêçä=mêçíçÅçä
Default Serial Parameters
aÉÑ~ìäí=pÉêá~ä=m~ê~ãÉíÉêë
The following are the parameter settings for serial communication:
Baud Rate = 115K baud
Parity = NONE
Stop Bit = 1
Data Bit = 8
Echo = ON
Flow Control = NONE
aÉÑ~ìäí=fm=^ÇÇêÉëë
The MatrixPRO default IP address is 192.168.000.243.
Please note:
The system returns to this value after a factory reset.
This default address can be changed using the menu system. In Chapter 4, refer
to the “IP Address” section on page 37 for instructions.
Note
These are the default settings, but only the baud rate can be
changed serially, or using the menu. In Chapter 4, refer to the
RS-232 Settings Menu
” section on page 37 for instructions.