Safety
Note: The Security submenu is protected with a password. Store the password in a safe
place!
Password (S6.5.1)
The application selection can be protected against unauthorized changes with the Password
function (S6.5.1).
By default, the Password function is not in use. If you want to activate the function, enter the
edit mode by pressing Menu Button Right. A blinking zero appears in the display and you can
set a password with the Browser buttons. The password can be any number between 1 and
65535.
Note: You can also set the password by digits. In the edit mode, push Menu Button Right
again and another zero appears on the display. Set ones first. To set the tens, press
Menu Button Right, and so on. Confirm the password with the ENTER button. After
this, you have to wait until the Timeout time (P6.6.3) (see Page 5-24) has expired before
the password function is activated.
If you try to change applications or the password itself, you will be prompted for the current
password. Enter the password with the Browser buttons.
You can deactivate the password function by entering the value 0.
Figure 5-16: Password Setting
Note: Store the password in a safe place! No changes can be made unless a valid password
is entered.
Password
Or
0
56.5.1
Password
56.5.1
Password
00
56.5.1
Not in use