Juniper Networks 8 Router User Manual


 
ERX 8.0.x Hardware Guide
Category Specification
Space Requirements
3 feet (90 cm) behind router or rack
Do not block air vents on sides of the router.
Donotplaceequipmentthatexhaustshotairtoleft
on the right of the router.
Be aware that router exhausts hot air from its left side.
Airflow
Airflow direc
tion is in through the right side and out
through the left side. See Figure 51.
NEBS Certification
SR-3580 (FD-15): Network Equipment Building
System (NEBS) Criteria Levels, I ssue 1, November
1995
GR-63–CORE: Network Equipment Building System
(NEBS) Requirements: Physical Protection, Issue 2,
April 2002
GR-1089 (LSSGR, FD-15): Electromagnetic
Compatibility and Electrical Safety - Generic Criteria
for Network Telecommunications Equipment, Issue
2, Revision 1, February 1999
Safety Agency Certification
AS/NZS 60950:2000 Safety of Information
Technology Equipment
CAN/CSA-C22.2, No. 60950-1–03, First Edition,
Information Technology Equipment - Safety - Part
1: General Requirements
EN60825-1, Safety of Laser Products - Part 1:
Equipment Class, Requirements, and User’s Guide
(2001)
EN60950-1:2001, First Edition, Information
Technology Equipment - Safety - Part 1: General
Requirements
IEC 60950-1(2001-10) Ed. 1.0 Information
Technology Equipment - Safety - Part 1: General
Requirements
Low Voltage Directive (73/23/EEC)
UL 60950-1, First Edition, Information Technology
Equipment - Safety - Part 1: General Requirements
126 ERX-310 Router Specifications