Lincoln Electric 200 Welder User Manual


 
TROUBLESHOOTING & REPAIR
F-43 F-43
PIPELINER® 200
This is the typical DC welding output
voltage generated from a properly
operating machine. Note that each
vertical division represents 20 volts
and that each horizontal division
represents 5 milliseconds in time.
The machine was loaded with a
resistance grid bank.
Note: Scope probes connected at
machine output terminals.
SCOPE SETTINGS
Volts/Div.....................20V/Div.
Horizontal Sweep.....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal
TYPICAL DC WELD VOLTAGE WAVEFORM
MACHINE LOADED SELECTOR SWITCH AT MAXIMUM
MACHINE LOADED TO 200 AMPS AT 40VDC
0 volts
5 ms
20 volts
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC