TROUBLESHOOTING & REPAIR
F-63 F-63
PIPELINER® 200
RETEST AFTER REPAIR
Retest a machine:
• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the
machineʼs electrical characteristics.
OR
• If you repair or replace any electrical components.
ENGINE OUTPUT
Engine Mode No Load RPM Load RPM
Perkins Low Idle 1375-1425 NA
Perkins High Idle 1540-1650 1450-1600
Kubota Low Idle 1390-1410 NA
Kubota High Idle 1580-1600 1550-1600
GM (Gas) Low Idle 1340-1360 NA
GM (Gas) High Idle 1580-1600 1550-1600
WELDER DC OUTPUT
Current Control Current Selector Open Circuit Load Volts Load Amps
Rheostat Switch Voltage
Maximum Maximum 88-98 33-39 300
DC AUXILIARY POWER RECEPTACLE OUTPUT
Open Circuit Voltage Load Volts Load Amps
124-138 115-130 15.0
FIELD AMPS AND VOLTS
(Current Rheostat at Maximum)
Exciter DC Volts Main Shunt Field Amps RPM
123 - 137 2.10-2.70 1540-1600