Lincoln Electric 200 Welder User Manual


 
INSTALLATION
AA-2 AA-2
DC CURRENT RANGE
Fine Adjustment in each Range
40-300 Amps
DUTY CYCLE*
60%
RATED DC OUTPUT
VOLTS @ RATED AMPS
Lincoln Plus Rating
40V @ 200A
NEMA Rating
28V @ 200A
PIPELINER® 200D PERKINS
1. Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to
rated capacity. When welding, available auxiliary power will be reduced.
* Based on a 10 minute period.
HEIGHT WIDTH DEPTH WEIGHT
40.94** in. 24.00 in. 66.50in.
1039.9 mm 609.6 mm 1689.1 mm 1318 lbs. (598 kg.)
**Top of enclosure, add 8.0” (203.2mm) for exhaust
Auxiliary Power
1
*
1.80 kW, 15 Amps @ 120V DC @ 35% Duty Cycle
PHYSICAL DIMENSIONS
TECHNICAL SPECIFICATIONS - Pipeliner® 200D (K6090-9)
DESCRIPTION
200 Amp DC Welder
All Copper Windings
Pure DC Power
Generator
Make/Model Description Horsepower Operating
Displacement
cu. in.(ltrs)
Starting Capacities
SPEED System
INPUT - DIESEL ENGINE
Perkins
104.22
4 Cylinder
4 Stroke
Naturally
Aspirated
Water
Cooled
Engine
28.2 HP
@ 1600RPM
High
1600RPM
Full Load
1550RPM
Low Idle
1400RPM
135.6 (2.2)
12VDC Battery
and starter
Push Button
Starter
(650 Cold
crank amps)
Fuel:
15gal.
(57L)
Oil: 8.7 qts.
(8.2L)
Radiator Coolant
9.5 qts.
(9.0L)
RATED OUTPUT @ 104°F(40C°) - WELDER
RATED OUTPUT @ 104°F(40C°) - GENERATOR
LUBRICATION FUEL SYSTEM GOVERNOR
Full Pressure with Full Flow Filter Indirect Fuel Injector Mechanical Governor
Electrical Shutoff Solenoid
Mechanical Fuel Pump
AIR CLEANER ENGINE IDLER MUFFLER ENGINE PROTECTION
Low noise Muffler: Shutdown on low oil
Single Element Automatic Idler Made from long life, pressure and engine
aluminized steel. temperature.
ENGINE COMPONENTS
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC