Lincoln Electric 200 Welder User Manual


 
OUTPUT PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
The engine will not return to low
idle when the welding and
auxiliary loads are removed.
1. Make sure the idler control
switch is set to the “Auto”
position.
2. Make sure both welding and
auxiliary loads are removed.
3. Check for mechanical
restrictions in the idler and
throttle linkage (PERKINS
code 10929 ONLY) There may
be a problem with the ECU or
Throttle Body Controller or
associated engine control
components on Kubota Diesel
(1114, 11316) and GM
Gas(10660, 10913,
11136)Contact the Lincoln
Electric Service Dept. 1-888-
935-3877.
1. Check the idler control switch
and associated leads for
loose or faulty connections.
See the Wiring Diagram.
2. Check the CURRENT
SENSING PC BOARD
Perform the Current Sense
Board Test. Replace if
necessary.
3. Perform the Idler Solenoid
Test. (PERKINS 10929
ONLY)
4. Check for loose or faulty
connections at the idler PC
board (PERKINS) ECU in
Kubota and Throttle Body
Controller GM 3.0 liter.
5. The idler PC board
(PERKINS) ECU in Kubota or
Throttle Body Controller -GM
3.0 liter may be faulty.
Contact the Lincoln Electric
Service Dept. 1-888-935-
3877.