Lincoln Electric 200 Welder User Manual


 
WELDING PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
The engine “cranks” AND starts,
but runs only about 30-60
seconds and shuts down.
1. Make sure the correct grade
and amount of oil is in the
engine crankcase. See the
Maintenance Section of this
manual.
2. Make sure the engine is not
overheating.
3. Make sure the engine
alternator is operating properly.
1. The oil pressure switch may
be faulty. Perform the Oil
Pressure Switch Test.
2. The Temperature Switch may
be fault. Perform the
Temperature Switch Test.
3. The alternator may be faulty.
Perform the Alternator Test.
4. The Idler/Engine Protection
Board may be faulty
(PERKINS) The ECU
(KUBO11:29 AMA) or Throttle
Body Controller (GM 3.0 Liter)
may be faulty. Contact the
Lincoln Electric Service Dept.
1-888-935-3877.
The welding arc is loud and
spatters excessively.
1. The current setting may be too
high for the electrode and
process.
2. The polarity may be wrong for
the electrode and process.
1. Check the engine speed.
High idle speed should be
1800 RPM. If Necessary,
perform the Engine Throttle
Adjustment Test. (PERKINS
ONLY 10929)
2. Check the main DC generator
brushes for good commutation
and alignment. Contact the
Lincoln Electric Service Dept.
at 1-888-935-3877.
The welding arc frequently
“pops out”.
1. The fine current control field
rheostat may be set too low for
the process and electrode.
2. Check the welding cables for
loose or faulty connections.
1. Check the engine speed. High
idle speed should be 1800
RPM. If Necessary, perform the
Engine Throttle Adjustment
Test. (PERKINS ONLY 10929)
2. The Current Range Selector
Switch may be faulty. Check
for proper operation and
contact.
3. Check the DC generator
brushes for good commutation
and alignment. Contact the
Lincoln Electric Service Dept.
at 1-888-935-3877.
TROUBLESHOOTING & REPAIR
F-10 F-10
PIPELINER® 200